三相電能質(zhì)量分析儀
如果您對該產(chǎn)品感興趣的話,可以
產(chǎn)品名稱: 三相電能質(zhì)量分析儀
產(chǎn)品型號: FLUKE433/434
產(chǎn)品展商: 其他品牌
產(chǎn)品文檔: 無相關(guān)文檔
簡單介紹
Features Complete three-phase troubleshooting tool: measures virtually every power system parameter : voltage, current, frequency, power, power consumption (energy), unbalance and flicker, harmonics a
三相電能質(zhì)量分析儀
的詳細(xì)介紹
Technical Data |
Inputs |
Number: |
4 voltage and current (3 phases + neutral) |
Maximum voltage: |
1000 Vrms (6 kV peak) |
Maximum sampling speed: |
200 kS/s on each channel simultaneously | |
Volt/Amps/Hertz |
Vrms (AC + DC) |
|
Measurement range: |
1 ... 1000 V |
Accuracy: |
0.5% of Vnom |
|
|
Vpeak |
|
Measurement range: |
1 ... 1400 V |
Accuracy: |
5% of Vnom |
|
|
Crest factor |
|
Measurement range: |
1.0 ... > 2.8 |
Accuracy: |
±5% |
|
|
Arms (AC + DC) |
|
Measurement range: |
0 ... 20 kA |
Accuracy: |
±1% ± 5 counts |
|
|
Apeak |
|
Measurement range: |
0 ... 5.5 kA |
Accuracy: |
5% |
|
|
Crest factor |
|
Measurement range: |
1 ... 10 |
Accuracy: |
±5% |
|
|
Hz (60 Hz nominal) |
|
Measurement range: |
51.00 ... 69.00 Hz |
Accuracy: |
±1% ± 5 counts | |
Dips and swells |
Vrms (AC+DC) ³ |
|
Measurement range: |
0.0% … 100% of Vnom |
Accuracy: |
±1% of Vnom |
|
|
Arms (AC+DC) ³ |
|
Measurement range: |
0 ... 20 kA |
Accuracy: |
±1% ± 5 counts | |
Harmonics |
Harmonic (interharmonic) (n) |
|
Measurement range: |
DC, 1..50; (Off, 1..49) measured relative to fundamental or to total rms |
|
|
Vrms |
|
Measurement range: |
0.0 … 1000 V |
Accuracy: |
±5% ± 2 counts |
|
|
Arms |
|
Measurement range: |
0.0 … 4000 mV x clamp scaling |
Accuracy: |
±5% ± 5 counts |
|
|
Watts |
|
Measurement range: |
Depends on clamp scaling |
Accuracy: |
±5% ± n x 2% or reading, ± 10 counts |
|
|
DC voltage |
|
Measurement range: |
0.0 … 1000 V |
Accuracy: |
±5% ± 10 counts |
|
|
THD |
|
Measurement range: |
0.0 … 100.0% |
Accuracy: |
±2.5% |
|
|
Hz |
|
Measurement range: |
0 … 3500 Hz |
Accuracy: |
± 1 Hz |
|
|
Phase angle |
|
Measurement range: |
-360º ... +360º |
Accuracy: |
± n × 1.5º | |
Power and energy |
Watt, VA, VAR |
|
Measurement range: |
1.0 … 20.00 MVA¹ |
Accuracy: |
±1.5% ± 10 counts |
|
|
kWh, kVAh, kVARh |
|
Measurement range: |
00.00 …200.0 GVAh¹ |
Accuracy: |
± 1.5% ± 10 counts |
|
|
Power Factor/ Cos Ф / DPF |
|
Measurement range: |
0…1 |
Accuracy: |
± 0.03 | |
Flicker |
Pst (1 min), Pst, Plt, PF5 |
|
Measurement range: |
0.00 … 20.00 |
Accuracy: |
±5% | |
Unbalance |
Volts |
|
Measurement range: |
0.0 … 5.0% |
Accuracy: |
±0.5% |
|
|
Current |
|
Measurement range: |
0.0 … 20% |
Accuracy: |
± 1% | |
Transient Capture |
Volts |
|
Measurement range: |
±6000 V |
Accuracy: |
±2.5% of Vrms |
Minimum detect duration |
5 µs (200kS/s sampling) | |
Inrush mode |
Arms (AC+DC) |
|
Measurement range: |
0.000 … 20.00 kA¹ |
Accuracy: |
±1% of meas ± 5 counts | |
Autotrend recording |
Sampling: |
Up to 100 readings/s continuous sampling per channel |
Memory: |
Up to 3600 min, max and avg points for each reading |
Recording time: |
Up to 450 days |
Zoom: |
Up to 12x horizontal zoom | |
Memory |
Screens: |
Fluke 434 - 50; Fluke 433 - 25 |
Data sets including recordings: |
Fluke 434 - 10; Fluke 433 - 5 | |
Notes |
¹ |
Depending on clamp scaling |
² |
50 Hz/60 Hz nominal frequency according to IEC 61000-4-30 |
³ |
Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle | |
Environmental Specifications |
Operating temperature |
|
0 ºC to +50 ºC (32 ºF to 122 ºF) | |
Storage temperature |
|
-20 ºC to +60 ºC (-4 ºF to 140 ºF) | |
Operating Altitude |
|
Standards |
Measurement methods used |
|
Power Quality |
|
Flicker |
|
Harmonics |
|
Safety Specifications |
Compliance |
|
IEC/EN61010-1 (2nd edition) pollution degree 2; |
|
CAN/CSA C22.2 No 101.1 |
|
ANSI/ISA S82.01 | |
Mechanical & General Specifications |
Size |
|
256 x 169 x 64 mm (10 x 6.6 x 2.5 in) | |
Weight |
|
Warranty |
|
Battery life |
Rechargeable NiMH pack: |
>7 hours |
Charging time: |
4 hours typical | |
Shock & Vibration |
|
Case |
|
IP51 (dust, drip, waterproof) | |